Description

Application Scenarios
Consider a packaging machine line where a control cabinet houses a MicroLogix or CompactLogix PLC, several analog and digital I/O modules, a PanelView HMI, and a bank of proximity sensors on the conveyor infeed. Every one of those devices depends on a clean, stable 24 V DC supply. When the original power supply begins to drift—output voltage sagging under peak sensor load—the PLC experiences intermittent I/O faults and the HMI flickers during machine cycles. Rather than chasing phantom wiring problems, the maintenance team identifies the root cause: an underrated, aging PSU. They replace it with a verified Allen-Bradley 1606-XLE80E-2, whose adjustable 24–28 V output easily compensates for voltage drop across the DC distribution wiring. Within minutes, the I/O faults disappear and the line returns to full production.
This scenario captures the everyday value of the 1606-XLE80E-2. It is not the most glamorous component in the cabinet, but it is the one every other component depends on. For OEMs building machinery for export, the 100–240 V AC universal input means a single PSU model works on any continent—no region-specific variants, no costly redesigns. For end users, stocking a spare 1606-XLE80E-2 is inexpensive insurance against the most common cause of unexplained control-system resets.
Parameter
| Main Parameters | Value/Description |
|---|---|
| Product Model | 1606-XLE80E-2 |
| Base Catalog Number | 1606-XLE80E |
| Manufacturer | Allen-Bradley / Rockwell Automation |
| Product Category | Switched-Mode Power Supply (Essential line) |
| Output Voltage | 24 V DC nominal, adjustable 24–28 V DC |
| Output Current | 3.3 A @ 24 V DC; 2.9 A @ 28 V DC |
| Output Power | 80 W |
| Input Voltage (AC) | 100–240 V AC, 50/60 Hz (wide-range universal) |
| Input Voltage (DC) | 110–300 V DC |
| Rated Input Current | 0.68 A typical; 1.24 A @ 100 V AC |
| Efficiency | 89.8% typical |
| Power Loss | 9.1 W typical |
| Ripple & Noise | ≤ 50 mVpp (20 Hz – 20 MHz) |
| Power Factor | 0.56 typical |
| Hold-Up Time | > 60 ms @ 120 V AC |
| Inrush Current | 23 A @ 120 V AC / 45 A @ 230 V AC, NTC-limited |
| Recommended Input Fuse | Minimum B-10 A or C-6 A |
| Power Boost | Dynamic 120% below 45 °C ambient |
| Output Stabilization | Regulated / stabilized output |
| DC OK Indication | LED status indicator |
| Protection Rating | IP20 |
| Electrical Connection | Screw terminals |
| Mounting | 35 mm DIN rail (EN 60715 / EN 50022); wall-mount optional |
| Operating Temperature | -25 °C to +70 °C (derating 1.8 W/°C above 60 °C) |
| Storage Temperature | -25 °C to +85 °C |
| Relative Humidity | 5–95% non-condensing |
| Vibration Resistance | 2 g |
| Shock Resistance | 30 G, 6 ms / 20 G, 11 ms |
| MTBF | 2,243 kh @ 40 °C (SN 29500) |
| Service Life | 77 kh minimum @ +40 °C |
| Dimensions (W × H × D) | 32 × 124 × 102 mm (1.26 × 4.88 × 4.02 in.) |
| Weight | 430 g (0.95 lb) |
| Certifications | cULus Listed (UL 508, E198865), cURus (UL 60950-1), CE, CSA C22.2, NEC Class 2, RCM, GOST, KC |
| Product Status | Active / Preferred |
| Special Features | Conformal coating available; redundancy-ready |